 |  |  | INOZINC is a two-component water base inorganic zinc silicate primer. |  |  |  |
 |  |  | INOZINC is recommended to be used directly to metal as a self-priming primer/coat to provide a long term protection of steel structures against corrosion. Typical uses are for structural steel, bridges, all marine and land-based oil and gas production facilities, and all steel structures exposed to severe weather conditions or exposed to moderate chemical spillage and fumes. |  |  |  |
 |  |  | • Excellent long-term performance without topcoating even in marine?environment. • Single coat application is sufficient for excellent protection even on surfaces contaminated by firmly adherent rusts.
 • Fast cure, water resistance and hardness are developed in 2 hours.
 • Resistance to mud cracking even at 125 microns thickness.
 • Easy to repair, low cost maintenance.
 • Water base, equipment can be cleaned up with water.
 • Self-inspecting over organic contaminants, film cracks and disbonds immediately if applied over a contaminated surface.
 • Cost advantage over multi-coat systems.
 • Suitable to be topcoated, when required, by epoxy coatings.
 
 |  |  |  |
 |  |  | | • Method of Application : | Conventional spray, nylon or polyester bruch for small area	only. 						When applying INOZINC Primer it is	important to keep the product				stirred and to maintain a flow to prevent zinc settling in the spray 						lines. Also, it is vital to use spray equipment that has not been 									contaminated with organic solvents |  | • Mixing Ratio : | 3Kg (Comp A) to 7Kg (Comp B) |  | • Mixing : | Add Comp.B (powder) to Comp. A (liquid) and stir well before 	application in order to ensure that a uniform consistency	is achieved. 	Never mix more material than can be used within potlife.	Mixed 	materials not used within potlife must be discarded. |  | • Pot life : | 8 hours (higher temperatures will shorten polife sharply). |  | • Thinner / Cleaner : | Do not thin. Clean applying tools by hot water. |  | • Application Temperature : | 5-40 ?C at a RH not more than 85% . |  | • Curing : | The reaction between the two-component (A & B) can not be	guaranteed 	unless a temperature of at  least 5°C is maintained for the mixture and the 	substrate until complete curing. Temperature of 	substrate should be at 	least 3°C above dew point to avoid moisture condensation during 	application. Relative humidity during application and initial drying    	should not exceed 85%. |  | • Note : | •	Coated surfaces by INOZINC should not be exposed to water, chemical fumes, or mechanical stresses before it is fully cured. | 
 |  |  |  |
 |  |  | | • Component A : | liquid |  | • Component B : | powder |  | • Color : | grey |  | • Gloss : | flat |  | • Volume Solids : | 65 % |  | • VOC : | 0.0 g/L |  | • Flexibility : | Very Good |  | • Solvent Splash and Spill Resistance : | Excellent |  | • Temperature Resistance : | 375 ?C |  | • Recommended film thickness : | 75-125 microns “dry” |  | • Theoretical spreading rate : | 8.7 m²/L at 75 microns “dry” |  | • Water resistance : | Excellent |  | • Abrasian Resistance : | Excellent |  | • Number of Coats : | 1 |  | • Specific Gravity (mixed) : | 2.79	kg/L (DIN 51757). |  | • Packaging : | Component A (liquid) 											: 3 Kg in 1 metal can Component B (powder) 										: 7 Kg  in 1 metal can |  | • Weather Resistance : | Excellent | 
 |  |  |  |
 |  |  | Well-prepared-surfaces is an essential condition of coating successfulness. In general, surface must be clean, dry, undamaged and free of all contaminants prior to coating. STEEL or GALVANIZING:
 Remove all oil , grease, wax…etc from the surface to be coated by thinner S100 or S405.
 Apply INOZINC as soon as possible after surface preparation to prevent any contamination.
 
 |  |  |  |
 |  |  | | • Dry to Touch : | 15 minutes (ASTM-D1640). |  | • Dry to Handle : | 30 minutes (ASTM-D1640). |  | • Fully Cured : | 2 hours |  | • Note : | Drying times can be affected by many factors such as temperature, ventilation and coat thickness. Relative humidity should not exceed 85%. Higher temperatures will shorten the drying times. | 
 |  |  |  |
 |  |  | • Keep components A & B in a cool and well ventilated place, protected 	from freeze, heat and direct sunlight. • Shelf life is two years from packing date in unopened original containers at 5 to 40°C. Containers should be kept tightly closed.
 Safety:
 • Well ventilated conditions should be provided during application.
 • Do not breathe or inhale mist.
 • Wear air-mask and avoid skin or eye contact.
 • This Product is for professional use only. Not for residential use.
 
 |  |  | 
 |  |  
                                |  | 
                                        
                                            information in this data sheet and in all our data sheets are given to the best
                                            of our knowledge based on laboratory testing and practical experience. Final results
                                            depend on following instructions and on consumer skill. Our responsibility is limited
                                            to providing products that Conform to samples and specimens provided by us. Due
                                            to technical needs, we reserve the right to change any given specification without
                                            notice. |  |  |