| EPX 08 is a two-component high-solid special epoxy coating for lining tanks containing acids and alkalis in high concentrations at temperatures up to 80°C.
| | |
| lining internal steel and concrete tanks, valves and pipes in all industries dealing with acids or alkalis in high concentration with temperatures. | | |
| • Economical tank lining coating for acids and alkalis storage and processing. • Excellent temperatures resistance up to 80° C when it immersed in acids or alkalis. • Excellent chemical resistance. • Excellent for protecting tanks from rust and corrosion . • Excellent abrasion resistance. • Excellent adhesion on concrete and metal surfaces. • Applied in two coats, does not require any primer or topcoat when blasting is applied. • Easy and low-cost maintenance due its smooth surface and its high dust resistance.
| | |
| • Method of Application : | Airless spray, brush or roller. | • Mixing Ratio : | (by volume) 1.6 to 0.9 (A to B). | • Mixing : | The individual components of EPX08 should be thoroughly stirred before
the two are mixed together. Combine components (A &B) in supplied proportions and
mix thoroughly using a slow speed mixer for at least 3 minutes to achieve uniform
consistency; “DO NOT USE HIGH SPEED MIXER”. Never mix more material than can
be used within pot life. Material that has begun to set must be discarded.
| • Pot life : | (20° C) 30 minutes (higher temperatures will shorten the pot life sharply).
| • Cleaner : | S405 "also known as Epoxsol" | • Thinner / Cleaner : | for most applications, no thinner is required. If thinning is
necessary a minimal amount of S405 (also known as Epoxsol) can be used.
| • Note : | • When recoating, a special attention should be given toward drying times
“minimum & maximum recoating time”. Any delay in applying interval coats may
request sanding the surface of the previous coat to ensure good adhesion.
• The reaction between the epoxy and its curing agent (A &Bcan not be guaranteed unless a temperature of at least 10 °C is maintained for the mixture and the substrate until complete curing. Temperature of substrate should be at least 3°C above dew point to avoid moisture condensation during application.
• Coated surfaces by EPX08 should not be exposed to water, chemicals, or mechanical stresses before it is fully cured.
|
| | |
| • Component B : | CAT20 | • Color : | Transparent | • Gloss : | Gloss (ASTM-D1523) | • Volume Solids : | 82 % (ASTM-D2697 | • Flexibility : | Very good | • Temperature Resistance : | Excellent | • Recommended film thickness : | 500 microns “dry” | • Theoretical spreading rate : | 1.65 m²/L at 500 microns “dry” | • Water resistance : | Excellent | • Abrasian Resistance : | Excellent | • Chemical Resistance : | Excellent | • Number of Coats : | 2 | • Specific Gravity (mixed) : | 1.1 kg/L (ASTM-D1475) | • Packaging : | Component A “base” 1.6 L in a metal can Component B “drier” 0.9 L in
a metal can (CAT20) .
|
| | |
| Surface Preparation Proper surface preparation is essential to ensure coating success, performance, and longevity. In general, all surfaces must be clean, dry, undamaged, and free of contaminants prior to application. STEEL ? Non-immersed surfaces: Abrasive blast to Sa2 in accordance with ISO 8501-1, achieving a surface profile of 50–100 µm. ?Immersed surfaces: Abrasive blast to Sa2½ (near-white metal finish) as per ISO 8501-1, with a surface profile of 50–100 µm. Aged or previously coated steel: Abrasive blast to Sa3 according to ISO 8501-1, ensuring a surface profile of 50–100 µm. Additional Instructions : • Thoroughly remove all abrasive residues and dust from the prepared surface. • Eliminate oil, grease, wax, and similar contaminants using S405 thinner (Epoxsol). •Apply the coating system (EPX08) as soon as possible following surface preparation to prevent recontamination. Blasted steel must not be left exposed overnight. •If immediate application of EPX08 is not feasible, a thin layer of EPX02 primer is strongly recommended as a temporary protective coating. • Prior to the application of EPX08 over EPX02, ensure the primed surface is clean, completely dry, and free from oil, grease, or any other contaminants. CONCRETE ?New concrete: Must be cured for at least 28 days at 21°C and 50% RH, or for an equivalent duration based on temperature and humidity. EPX17 primer may be applied once the concrete has cured for at least 14 days at 21°C and 70% RH. ?Old concrete: Remove surface irregularities such as fins and protrusions by stoning, sanding, or grinding. Abrasive blasting is the most effective method to remove previous coatings, form oils, laitance, and other foreign matter. • Fill small holes and voids with STOP200 before applying EPX08. • For highly porous concrete or poorly ventilated areas where solvent vapors are a concern, EPX17 is recommended as the primer. If the surface has low absorption, EPX02 is a more suitable choice.
| | |
| • Dry to Touch : | 4 hours (ASTM-D1640). | • Dry to Handle : | 8 hours “minimum recoat time”, 24 hours “maximum recoat time”
(ASTM-D1640).
| • Fully Cured : | 7 days. | • Note : | Drying times can be affected by many factors such as temperature,
ventilation and coat thickness. Higher temperatures will shorten the drying times.
|
| | |
| • Economical tank lining coating for acids and alkalis storage and processing. • Excellent temperatures resistance up to 80° C when it immersed in acids or alkalis. • Excellent chemical resistance. • Excellent for protecting tanks from rust and corrosion . • Excellent abrasion resistance. • Excellent adhesion on concrete and metal surfaces. • Applied in two coats, does not require any primer or topcoat when blasting is applied. • Easy and low-cost maintenance due its smooth surface and its high dust resistance.
| |
|
|
|
information in this data sheet and in all our data sheets are given to the best
of our knowledge based on laboratory testing and practical experience. Final results
depend on following instructions and on consumer skill. Our responsibility is limited
to providing products that Conform to samples and specimens provided by us. Due
to technical needs, we reserve the right to change any given specification without
notice.
|
|
|