Top
EPX08
Description
EPX08 is a two-component (A & B) water-based epoxy.
Recommended Uses
EPX08 is used as a primer/sealer for concrete surfaces. Typical uses, with a suitable coating systems, are in chemical plants, textile factories, hospitals, food and beverage industries, and pharmaceutical industries …etc.
Features
1- Penetrates and seals concrete surfaces and improve concrete properties.

2- Can be mixed with masonry to improve its mechanical specification.

3- Excellent resistance to water, sea water, salt solutions, alkalis, detergents, white spirits, aliphatics, mineral oils and fatty oils (A separate leaflet CHR01 is available).

4- No harmful vapors and scents are present (makes it easy to use and to apply even in confined areas)
Application Instruction
• Method of Application : Brush, roller or spray gun.
• Mixing Ratio : (by volume) 4 to 1 (A to B)
• Mixing : The individual components of EPX08 should be thoroughly stirred before the two are mixed together. Combine components (A & B) in supplied proportions and mix thoroughly using a slow speed mixer for at least 3 minutes to achieve uniform consistency; “DO NOT USE HIGH SPEED MIXER”. Never mix more material than can be used within potlife. Material that has begun to set must be discarded.
• Pot life : 1.5 hours (higher temperatures will shorten the potlife sharply).
• Thinner / Cleaner : Water is used for thinning or cleaning. Due to potlife limitations, clean all mixing and applying tools by water immediately after application is completed
• Curing : The reaction between the epoxy and its curing agent (A & B) can not be guaranteed unless a temperature of at least 10°C is maintained for the mixture and the substrate until complete curing. Temperature of substrate should be at least 3°C above dew point to avoid moisture condensation during application.
• Note : 1- When recoating, a special attention should be given toward drying times “minimum & maximum recoating time”. Any delay in applying interval coats may request sanding the surface of the previous coat to insure good adhesion. 2- Coated surfaces by EPX08 should not be exposed to water, chemicals, or mechanical stresses before it is fully cured
Technical Information
• Component B : CAT70
• Color : Colorless
• Gloss : Semi-gloss (ASTM-D523)
• Volume Solids : 58 % (ASTM-D2697)
• Flexibility : Very good
• Recommended film thickness : 40-60 microns “dry”
• Theoretical spreading rate : 11.6 m²/L at 50 microns “dry”
• Water resistance : Excellent
• Abrasian Resistance : Very good
• Chemical Resistance : Good (A separate leaflet CHR01 is available)
• Solvent Resistance : Fair (A separate leaflet CHR01 is available)
• Number of Coats : 1
• Specific Gravity (mixed) : 1.05 kg/L (ASTM-D1475)
• Packaging : Component A 3.6 L in US Gallon Component B 0.9 L in US Quart
Surface Preparation
Well-prepared-surfaces is an essential condition of coating successfulness. In general surface must be clean, dry, undamaged and free of all contaminants prior to coating.

CONCRETE:

Remove fins and other protrusions by stoning, sanding or grinding.

New concrete: Must be cured at least 28 days at 21?C and 70% RH, or equivalent time.

Old concrete: Abrasive blasting is best to remove all previous coatings, form oils, laitance and other foreign matter. Fill small holes or voids with STOP200 before applying EPX08.
Drying Time
• Dry to Touch : 2 hours (ASTM-D1640).
• Dry to Handle : 12 hours “minimum recoat time”, 24 hours “maximum recoat time” (ASTM-D1640).
• Fully Cured : 7 days.
• Note : Drying times can be affected by many factors such as temperature, ventilation and coat thickness. Higher temperatures will shorten the drying times.
Storing Conditions
1- Epoxy system, in general, has to be kept in a cool and well ventilated place, protected from heat and direct sunlight.

2- Shelf life is one year from packing date in unopened original containers at 10 to 40°C. Containers should be kept tightly closed.

Safety:

1- Well ventilated conditions should be provided during application.

2- Do not breathe or inhale mist.

3- Wear air-mask and avoid skin or eye contact
Notice:

information in this data sheet and in all our data sheets are given to the best of our knowledge based on laboratory testing and practical experience. Final results depend on following instructions and on consumer skill. Our responsibility is limited to providing products that Conform to samples and specimens provided by us. Due to technical needs, we reserve the right to change any given specification without notice.

Download as PDF